Our website uses cookies. They help us understand how customers use our website so we can give you the best experience possible. By continuing to browse this site or choosing to close this message, you give consent for cookies to be used. The cookies are not used for advertising. This applies to visitors from EU.

Crawford Cdm9 950 Installation Manual Direct

Reconnect motor, press push button. Door must open smoothly, hold, close.

Activate E-stop – door stops within 10 mm of travel. 8. Troubleshooting | Problem | Likely Cause | Remedy | |------------------------|-------------------------------|----------------------------------| | Door does not move | No power, blown fuse | Check input supply, replace fuse | | Door reverses randomly | Sensor misalignment | Clean & align photocells | | Unusual belt noise | Low belt tension | Re-tension belt | | Slow operation | P01/P02 set too low | Increase speed parameter | 9. Maintenance Schedule | Interval | Action | |----------------|------------------------------------------| | Monthly | Clean rail, check belt tension | | Quarterly | Lubricate carrier wheels (silicone spray)| | Annually | Backup battery test, controller firmware check | 10. Specifications | Parameter | Value | |--------------------|---------------------------| | Max door weight | 200 kg per leaf | | Max width | 2500 mm per leaf | | Power supply | 230V AC, 1.5A | | Standby power | 12 W | | Protection class | IP20 | | Operating temp | -15°C to +50°C | Document version: 1.0 Compliance: EN 16005, ANSI/BHMA A156.10 ⚠️ This write-up is a general template. For official installation, always use the exact manual provided by Crawford. crawford cdm9 950 installation manual

Activate photocell during closing – door must reverse immediately. Reconnect motor, press push button